ELI-900

A large incubator that combines low temperature control with high capacity

Precise temperature control provides a stable environment.

This incubator is suitable for culturing, keeping warm, and storing at low temperatures.

It can be used not only for culturing microorganisms, but also for storing powdered culture media and for sensory evaluation of food.
Furthermore, the glass interior door structure allows for observation of the interior while minimizing temperature fluctuations.

Low temperature control

It can be set in the temperature range of 3℃~50℃.
In addition to culture, it can also be used as a low-temperature storage facility for powder media, etc.


High-precision temperature distribution

The interior is controlled by ±1.0℃, making it ideal for storing delicate samples.
(at 20℃, center of the tank, measured at 3 points above, below and below)


Large capacity

The large-capacity tank can accommodate large amounts of culture, storage, and heat retention.
(Inner tank dimensions W1500×D600×H1000mm)

Double door structure

The interior of the storehouse has a glass interior door.
It maintains a stable culture environment by allowing you to check the internal condition without opening the door.


Sensor Port

Temperature sensor insertion hole is standard equipment.
Because measurements can be taken without opening the door, environmental fluctuations are minimized, and accurate and stable temperature control is achieved.


High load capacity (optional)

It can accommodate the storage of pail cans and 1-ton cans, and since no transfer is required, it allows for efficient operation

Large capacity

Have you ever wondered if you could grow more at once?
For example, in the case of test tubes, it can carry 2250 tubes. Efficient culture operations can also be performed on days of the week.
This single unit allows for flexible operation tailored to each specific application.

Φ18×180 test tube
(Rack size 130cm vertically × 122cm horizontally Array 5×5)
Layout example

High load capacity (optional)

Are you having trouble transferring samples?
By making it a high-load model, a large number of pail cans and one-to-one cans can be inserted.
Storing samples in a heated state increases their fluidity, supporting efficient operation.

20L pail can
(Top Φ300 × Bottom Φ275 × Height 370mm)
Layout example

Itto Can (18L)
(W238×D238×H349mm)
Layout example

Sensor Port

Do you open the door every time you install an external sensor or take a temperature measurement?
This device comes standard with a sensor insertion hole on the left side, allowing sensors to be introduced directly into the shed.
Because measurements can be taken without opening the door, validation and daily management can be performed while minimizing temperature fluctuations.

Double door structure

Do you open the door every time you check the interior and the temperature is disturbed?
By using a glass inner door in addition to the outer door, it is possible to check the condition of the interior without opening the door.
By eliminating unnecessary opening and closing, temperature fluctuations are reduced, resulting in a stable culture environment.

ELI-900
Tank dimensions W×D×H(mm) 1500×600×1000
Tank internal volume (L) 900
External dimensions WxDxH (mm) 1700×850×1900
Weight (kg) 350
Operating temperature (℃) 3 – 50
Refrigerator Air-cooled condensing type refrigerant type R134a
Required power supply AC100V, 20A or higher
Number of shelves (load capacity) 3 pieces each on the left and right, 6 pieces in total (25kg/piece)

Temperature overflow prevention device

The temperature indicator regulator monitors the temperature inside the tank and automatically shuts it down if it becomes abnormally high, protecting the sample inside the tank.

Independent anti-over-the-top device

In the unlikely event that the device becomes uncontrollable, it will automatically shut down once the set temperature is reached, ensuring the user's safety from the risk of fire or other hazards.

Fan motor malfunction

If a malfunction occurs in the blower motor, the motor and temperature control will stop and the heater circuit will be shut off, preventing the risk of fire and other hazards.

Sensor anomaly detection

An alarm will sound and stop operation if the temperature sensor fails.
Instruments crucial for temperature control prevent equipment from running out of control.

Heater break detection

An alarm will sound and stop operation when the current level drops due to a broken heater or other reason.

Ground fault breaker

Incubators that use liquids, etc
Due to its structure, it is difficult to completely eliminate the risk of electrical leakage.
Senses a power leakage in the equipment and turns off the main power supply.
The electrical circuit is shut off, preventing the user from being electrocuted.

Recording meters and temperature monitoring sensors

GMP requires reliable temperature monitoring and recording of the culture process.
ESTERI supports the addition of recorders and temperature sensors, allowing for constant monitoring and recording of the interior temperature.
By accurately understanding driving conditions and obtaining highly reliable data, we contribute to strengthening quality control.

High load capacity

When heating highly viscous oil or water stains, it is usually necessary to transfer them to a tapper or similar container.
With the ELI-900, the shelves are designed to be heavy-duty, allowing pail cans and one-to-one cans to be heated directly.
This eliminates the need for transfers and contributes to increased work efficiency through improved fluidity.

Added indicator light

Even if you are far away, you can still see the status of the device at a glance.
Adding indicator lights helps ensure smooth operation.

Enhanced freezing capacity

Even when using heat-generating equipment such as a vibrator inside the tank, a refrigerator with high refrigeration capacity compensates for the heat generation load and maintains the set temperature stably.

Why ESTERI?

Sterilization fast, easy, and reliable
Supporting essential hygiene practices in food and medical care
Japan's first sterilizer manufacturer

Over 50 years of experience

Sterilization technology in the laboratory and medical fields that has been developed since 1976

Quality based on international standards

"Manufacturing" that does not depend on individual abilities

Meeting customer needs

Flexible, custom-made solutions tailored to individual needs

To over 80 countries worldwide

Global brand of compact autoclaves

International standards certification obtained

Having trouble choosing a product?