EFV Series
The top-of-the-line autoclave model chosen by pharmaceutical companies
The EFV is a high-end model equipped with a vacuum pump for degassing.
It ensures reliable vapor penetration even for sterilized materials that tend to retain air, such as hollow materials and porous materials.
Furthermore, the addition of a drying function contributes to improving process efficiency after sterilization.
We consistently handle the sterilization and drying of objects that were previously considered difficult, such as jarfer mentors, elongated tubes, and dust-free clothing/masks, providing a higher level of sterilization quality and reliability.

Air venting using a vacuum pump
(Pre-vacuum function)
A vacuum pump forcibly removes air from inside the can.
It maximizes vapor permeability, ensuring reliable sterilization.
Extensive program features
Equipped with programs for handling liquids, equipment, and waste, sterilization can be easily performed by anyone.
Interactive interface
The LCD panel allows for easy operation by anyone with minimal keystrokes.
Double locking mechanism
It protects workers with a safety design that allows the footer to be unlocked only when the temperature and pressure are within a safe range.

Vacuum drying function
By creating a vacuum inside the can to lower the boiling point, the water droplets become more easily vaporized, resulting in more efficient drying.
Recording and managing driving data (optional)
The sterilizer and PC can be connected, and dedicated software can record the temperature, pressure, and time while the device is in operation.
It frees you from the hassle of handwriting.
A variety of additional options
- Printer (heat-sensitive)
- Product temperature sensor
- Data logging system
- High-altitude compatible settings
Air release using a vacuum pump (pre-vacuum)
Are you having trouble sterilizing complex shapes?
When it comes to sterilization, it's important to "remove the air."
By forcibly removing the air from the cans using a vacuum pump and replacing it with steam, EFV enabled the sterilization of complex shapes such as porous filters, endoscopic instruments, and gerfermenters that could not be processed in typical autoclaves.
による空気抜き.png)
Vacuum drying function
In drying, it is important to "effectively steam the water droplets."
EFV reduces the pressure inside the can using a vacuum pump, lowering the boiling point inside the can to approximately 60℃ and promoting efficient water evaporation.
This achieves a high level of drying efficiency, and since the entire process from sterilization to drying can be completed with the touch of a button, it contributes to shortening work time and improving on-site efficiency.


Interactive interface
The interactive interface on the LCD screen allows anyone to set driving conditions without making any mistakes.
This reduces rework caused by conditions being set incorrectly.
Additionally, you can check in detail the settings such as temperature, pressure, and process, as well as the operating conditions.

Recording and managing driving data (optional)
Are you experiencing the hassle of using sterile data?
This reduces rework caused by conditions being set incorrectly.
You can connect the sterilizer to a PC and record the temperature, pressure, and time while it's running using a dedicated application.
Furthermore, by integrating data into Microsoft Excel®and quantitatively verifying it, we support highly accurate sterilization operations.

Product temperature sensor (optional)
Have you ever struggled with setting a sterilization timer?
Sterilized materials such as liquids and solids do not transfer heat well and reach the sterilization temperature later than the displayed temperature. This is called 『sterilization time lag』.
With a product temperature sensor, a timer is started when the sterilized items reach temperature, efficiently maintaining the effective sterilization time and ensuring safe and reliable sterilization.



| EFV-62 | EFV-96 | EFV-117 | |
| Can diameter x effective height (mm) | Φ320×660 | Φ400×660 | Φ400×820 |
| Can volume (L) | 62 | 96 | 117 |
| External dimensions WxDxH (mm) | 555x810x980 | 625x910x980 | 625x910x1140 |
| Weight (kg) | 115 | 135 | 142 |
| Sterilization temperature (℃) | 100~140 | 100~129 | 100~125 |
| Sterilization time (hours: minutes) | 00:01 - 48:00 (common to all models) | ||
| Maximum pressure (MPa) | 0.290 | 0.200 | 0.170 |
| Number of driving programs | 16 | ||
| Required power supply | AC200V, single phase, 30A or higher | ||
1. Liquid “open”

It is suitable for sterilizing liquids in containers such as flasks, beakers, and vial bottles.
The purpose is to prepare sterile water, sterilize liquid media such as LB medium, NB medium, TSB medium, BHI medium, and EC broth, buffer solutions, physiological saline, and other liquid samples, or to keep them warm after sterilization.
2. Liquid “sealed”

It is suitable for sterilizing liquids in containers such as flasks, beakers, and vial bottles, which are capped with cotton or sponge stoppers.
The purpose is to prepare sterile water, sterilize or sterilize liquid media such as LB medium, NB medium, TSB medium, BHI medium, and EC broth, buffer solutions, physiological saline, and other liquid samples, and keep them warm.
3. Instruments

It is suitable for sterilizing complex instruments and other instruments with complex shapes that tend to retain air.
It is intended for the reliable sterilization of glass instruments, porcelain, metal instruments, silicone rubber, plastics, paper or textiles, as well as jarfermenters, endoscopic instruments, surgical instruments, filter cartridges, dust-free clothing, etc.
Furthermore, it can handle drying after sterilization, enabling efficient operation.
4. waste

It is suitable for sterilizing waste contaminated with microorganisms, cells, etc.
This product is intended for sterilizing mixed products such as used culture media, cleaning wastewater, pipette tips, petri dishes, and paper towels and wipes used for blotting, placed in sterile disposal bags or stainless steel containers.
5. Dissolution


Suitable for killing common bacteria at 75 ~85℃.
The purpose is to treat at 100℃ or less, and to keep sterilized powder culture media warm to prevent coagulation.
Furthermore, by pre-running this process using a calendar timer and keeping the equipment warm, the subsequent sterilization operation time can be further reduced.
6. Additional drying

After operation is complete, it will be used as an aid in case of insufficient drying.
Futa Interlock System - Futa Open/Close Detection
It features a sliding lever one-touch lock, ensuring both operability and safety.
If the footer is not securely locked, you will not be able to start driving.
It also features a double-locking mechanism that cannot be unlocked until the temperature and pressure are reduced.

Anti-firing function
If there is a water shortage, an alarm will sound and the system will automatically shut off.
This prevents overheating due to dry lighting and ensures the safety of the equipment and its users.

Ground fault breaker
Senses a power leakage in the equipment and turns off the main power supply.
It activates in the event of a water leak or electrical component failure, preventing electric shock to the user.
Vacuum pump protection circuit
It is equipped with protective features to maintain stable operation of the vacuum pump.
It automatically shuts off the power during overloads, preventing pump damage and improving long-term device reliability.
Temperature and pressure prevention function
An alarm will sound and heating will stop if the can temperature exceeds the set temperature and pressure while driving.
This can easily occur if too much sterile material is packed into the container.

Sensor break detection
An alarm will sound and stop operation if the temperature sensor fails.
Instruments crucial for temperature control prevent equipment from running out of control.

Pressure safety valve
It prevents the pressure from rising by allowing steam from inside the can to escape when the pressure rises to an abnormal level. This is a dual safety device that activates in the unlikely event that the electrical safety device malfunctions and the equipment goes out of control.
Product temperature sensor
The core temperature of the sterilized material rises later than the temperature of the can body. For example, 1 liter of liquid needs to reach 121℃ 10 minutes after the device reaches 121℃.
By positioning the tip of the product temperature sensor at the center of the liquid, not only can the liquid temperature be monitored, but "product temperature mode operation" is also possible, in which the timer starts counting down when the liquid reaches the set temperature.
This ensures that multiple types of sterilization under different conditions can be performed.


Recording and management of driving data
Are you experiencing the hassle of using sterile data?
This series connects a sterilizer to a PC, allowing you to record the temperature, pressure, and time while the device is in operation using a dedicated application.
Furthermore, by integrating data into Microsoft Excel®and quantitatively verifying it, we support highly accurate sterilization operations.

Printer (heat-sensitive)
Automatic printing will begin as soon as operation starts, and the process will be recorded, including the timing of sterilization timer operation. By automatically completing the printing process at the end of operation, the sterilization process is visualized accurately and effortlessly, contributing to more efficient and reliable record management.
- Settings
- Batch number
- temperature
- pressure
- Time
- Target temperature (optional)
- Error Code
- Maximum/Minimum/Average Sterilization Temperature

Recorders and temperature monitoring sensors (custom-made)
GMP requires reliable monitoring and recording of temperature during the sterilization process.
This series allows for the addition of recorders and temperature sensors to constantly monitor and record the temperature and pressure inside the can.
This ensures reliable understanding of sterilization conditions and reliable data acquisition, contributing to improved traceability and a stronger quality assurance system.

High altitude support (altitude 1000m or more)
At high altitudes, a decrease in air pressure can lower the boiling point of water, which can affect the temperature and pressure control of the autoclave.
This series allows for setting changes depending on altitude conditions, ensuring proper sterilization conditions even in high-altitude environments and achieving stable operation.

Wire mesh basket

Do not place sterile materials directly into the can body. This not only causes malfunctions but also leads to serious accidents. Be sure to place the sterile material in the wire mesh basket.
This series comes standard with the following wire mesh baskets: To sterilize liquids, place the container in a wire mesh basket or purchase a sterile container (accessory) sold separately.
| EFV-62 | EFV-96 | EFV-117 | |
| Inner diameter × height (mm) | Φ300x300 | Φ380x300 | Φ380x400 |
| Number | 2 | 2 | 2 |
| Product number | BW3030 | BW3830 | BW3840 |
Number of inserts

Threaded bottle (ISO standard)
| 100ml Φ56×100mm |
250ml Φ70×138mm |
500ml Φ86×176mm |
1000ml Φ101×225mm |
|
| Kago diameter Φ300 |
|
|||
| 19 bottles | 12 bottles | 8 pieces | 5 bottles | |
| Kago diameter Φ380 |
|
|||
| 31 bottles | 19 bottles | 13 bottles | 9 pieces | |
Number of inserts
| EFV-62 | 38 (57) books | 24 (36) books | 14 (21) books | 10 pieces |
| EFV96 | 62 (93) books | 38 (57) books | 28 (42) books | 18 bottles |
| EFV-117 | 62 (124) books | 38 (76) books | 28 (56) books | 18 bottles |
Wire mesh basket

We offer a variety of sizes. Please select based on the size of the sterilized items.
In that case, please pay attention to the diameter and effective height of the can body.
| Product number | Internal dimensions: Diameter × Height (mm) |
| BW3020 | Φ300×200 |
| BW3030 | Φ300×300 |
| BW3815 | Φ380×150 |
| BW3820 | Φ380×200 |
| BW3830 | Φ380×300 |
| BW3840 | Φ380×400 |
Kago bottom storage dish
Sterilizing waste materials such as used petri dishes can contaminate equipment by spilling molten liquid.
To prevent equipment failure due to this, you can store the liquid in the bottom of the wire mesh basket and take it in.

| Product number | Internal dimensions: Diameter × Height (mm) | Compatible basket interior dimensions |
| DH2896 | Φ289×60 | Φ300 |
| DH3636 | Φ363×60 | Φ380 |
Sterile container
When sterilizing large amounts of liquids, viscous substances, or soil,
Use a sterile container.
However, unlike wire mesh baskets, when used in layers, the bottom container
It traps air, resulting in poor sterilization.
Always use only one.

| Product number | Internal dimensions: Diameter × Height (mm) |
| VN2727 | Φ270×270 |
| VN3636 | Φ360×300 |
Why ESTERI?
Sterilization fast, easy, and reliable
Supporting essential hygiene practices in food and medical care
Japan's first sterilizer manufacturer
Over 50 years of experience
Sterilization technology in the laboratory and medical fields that has been developed since 1976
Quality based on international standards
"Manufacturing" that does not depend on individual abilities
Meeting customer needs
Flexible, custom-made solutions tailored to individual needs
To over 80 countries worldwide
Global brand of compact autoclaves
International standards certification obtained

Having trouble choosing a product?